Hello and welcome to the November UV-Guard Newsletter. In this edition, we remind our customers of the importance of regularly servicing UV disinfection systems. We also let our customers know our operating hours during the holiday period.



Has your UV system been serviced lately?

To maintain optimal performance and to ensure your UV system is achieving the correct level of disinfection, it’s important to service it regularly. Each component of your UV system has a recommended replacement schedule to ensure optimal performance. For example:

UV lamps need replacing annually (8,000 - 16,000 hours depending on type)
UV disinfection organisations promote their UV lamps as having a particular lamp life. Although a UV lamp may appear to be working past its lamp life, its disinfection capability decreases due to a reduction in generated UV-C light. In general, a UV lamp's intensity at the end of its lamp life has been reduced by 20% compared to a new lamp.

In addition to UV lamps being replaced, controller lamp timers need to be reset and UV intensity monitors need to be re-calibrated where applicable.

Quartz sleeves are recommended to be replaced every 2 years
The condition of a quartz sleeve plays a vital role in how well the UV light can penetrate the water or liquid. A dirty quartz sleeve blocks UV light from reaching the water, reducing the UV intensity in the UV reactor, resulting in a decreased UV dose. This increases the likelihood of pathogens passing through the UV reactor and not being adequately treated which is especially dangerous in potable or food and beverage applications. Quartz sleeves may become dirty to the point that they cannot be cleaned after 2 years and they also become brittle.

It must be noted that quartz sleeves should be inspected at regular intervals during the initial operation of a new system. This will give an indication of the cleaning frequency required and will establish if further pre-treatment is required to prevent quartz sleeve fouling. Another indication of a potentially fouled quartz sleeve is a UV intensity monitor. A drop in UV intensity may indicate a dirty quartz sleeve.

Quartz O-ring seals should be replaced annually  
The O-ring that creates the seal to prevent water from entering the quartz sleeve needs replacing each time the quartz sleeve is removed for cleaning. This should be annually as a minimum requirement. Failing to replace the O-ring will increase the chances of water reaching the lamp, resulting in lamp failure.

Depending on the system model, there may also be additional service actions required such as replacing quartz wiper blades. Manuals provided for each UV system model must always be followed.
Download UV-Guard manuals here

Are you shutting down for the holidays?


Many of our manufacturing clients who use UV disinfection, take advantage of the holiday shutdown period to service their UV systems. It’s a simple way to optimise production so you are ready for a great start in 2018.

UV-Guard maintenance support


We offer complete UV servicing and maintenance support for all brands of UV systems. Here are some advantages of using our services:
  • Our commercial electricians are experienced in servicing a variety of UV system models.
  • Our UV engineers can talk you through the steps required to ensure optimum disinfection.
  • We stock spare parts for all brands and models for Australia-wide and international expedited shipment.
Get in touch today!
Contact us

Operating hours for the holiday period


The UV-Guard office will be closed from Friday the 22nd of December and reopens on Tuesday the 2nd of January. During this period, the team can be contacted via sales@uvguard.com